Sistema de control de energía (ECS) 200 de Cat®
Consultar precio
The Cat® ECS 200 control panel provides all of the controls and system indicators in one easy to access interface for multiple generator set paralleling operations.
Características destacadas del producto
- Pantalla
- Off-Package Remote HMI; The Cat ECS 200 supports up to four optional full function remote HMI displays with the addition of an unmanaged Ethernet switch. The interactive color touchscreen graphical interface serves to display generator set system alarm conditions, status indications and annunciation facilitates compliance to NFPA110 (subject to local authority having jurisdiction approval)
- Anunciador Rs-485
- The remote RS-485 annunciator serves to display genset system alarm conditions and status indications for 16 points with a standard NFPA 99 and 110 label. The annunciator has been designed for use on the long-distance annunciator datalink and may be used in remote (up to 4000 feet) applications.
- A maximum of four annunciators may be used with a Cat ECS 200.
- Módulo de entrada/salida digital
- The digital input/output (DI/O) module serves to provide expandable input and output for any event and is capable of reading discrete inputs and setting relay outputs. The DI/O module has been designed for use on the accessory communication network and may be used in either local (package mounted) or off-package remote (up to 244 meters or 800 feet) applications.
- A maximum of six DI/O modules may be used with a Cat ECS 200.
- Módulo Rtd
- The RTD module serves to provide expandable generator set temperature monitoring capability of the Cat ECS 200 control system and is capable of reading up to eight type 2-wire, 3-wire and 4-wire RTD inputs. The RTD Module has been designed for use on the Accessory Communication Network and may be used in either local (package mounted) or off-package remote (up to 244 meters or 800 feet) application.
- Comunicaciones
- Expansion Input/Output Ethernet Modules- Supports expanded Inputs/Outputs (IO) capability of the Cat ECS 200 control: Analog and digital I/O and Temperature sensing (RTD)- Configure I/O for any event (read and write function)- Package mounted and/or ship loose options
- Multiple Generator Data Link (mgdl)
- MGDL is an ethernet-base communication protocol to accomplish a synchronizing and paralleling function between Cat ECS 200 and EMCP 4.4 controllers. Connected devices are limited to a maximum of 16 and certain Cat ECS 200 features are limited while using MGDL.