C280-6 Offshore Generator Set
Call for Price
The C280-6 generator set incorporates years of proven success of the 3600 engine with the latest technology in electronics. The result is a fully integrated solution that is ideal for offshore operations. Ideal applications for the C280-6 offshore generator set are main power on-board drilling and production vessels and platforms. Complete package offerings are MCS type-approved and compliant with IMO Tier II emissions standards, making integration of the Cat C280-12 generator set into the vessel a simplified operation. Cat generator sets are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty. Cat C280-6 offshore generator set. Ratings: 1760 - 1940 ekW @ 50 Hz (1000 rpm). IMO Tier II emissions compliant.
Product Highlights
- Width
- 71.6 in
- Length
- 293 in
- Height
- 107.6 in
- Lube Oil System - Refill
- 229 gal (US)
- Cooling System - Engine
- 105 gal (US)
- Air Inlet System
- 90° adapter and straight adapters for air inlet to turbocharger Air cleaners
- Air cleaners with Cat dry paper filter elements (approximately 99.9% efficient at filtering SAE fine dust)
- Soot filter
- Control System
- 4-20 mA load feedback signal
- Load sharing module
- Direct rack module
- Cooling System
- Separate Circuit Aftercooler (SCAC)
- Customer water connections
- Jacket water thermostats
- AC/OC thermostats
- Accessory module-mounted high volume expansion tank
- Jacket water heater
- Heat recovery connections and thermostats for use with water maker system
- ANSI connection adapters
- Exhaust System
- Exhaust manifold shields
- Vertical or 30° outboard exhaust orientation options
- Exhaust outlet expanders and weld flanges
- Fuel System
- Manual fuel priming pump
- Duplex primary fuel strainer
- Flexible fuel hose connections
- Lube System
- Dry engine-mounted sump system that gravity feeds into base assembly integral sump
- Engine-mounted duplex oil filter
- Intermittent air prelube
- Continuous electric prelube
- Redundant prelube with continuous electric prelube and intermittent air prelube backup
- Oil pan drain valves
- Electric continuous prelube pump
- Lube oil heater
- Protection System
- Wiring meets MCS requirements
- Upgrade PLC monitor to industrial PC
- Upgrades AC/OC, JW and start air pressure from contactors to transducers
- Raw water/sea water pressure transducer
- Modbus communication
- Beacon and horn
- Single engine remote display monitor
- Emergency pump start signal
- Cabinet cooler
- Generator power monitoring
- Remote relay panel
- Turbocharger speed sensors
- Cylinder pressure relief valve
- Oil mist detector
- Flywheel and damper guards
- Mounting System
- Base aseembly
- Vertically-restrained vibration isolators and weld plates
- Starting System
- Single turbine air starters
- Boost control valve for extremely cold ambient conditions
- Air start pressure reducing valves
- General
- Torsional couplings
- Mounting groups for engine, generator, and base
- Accessory module to mount attachments such as the expansion tank, heat exchanger, instrument panel and engine controls, annunciator panel, alarm and shutdown contactors, fuel strainer
- Flywheel
- Engine barring device options:
- One-year storage preservation
- Oceanic transportation shipping protection (shrink wrap and tarp)
- Engine testing — certified dynamometer test, fuel consumption test, rated speed performance test, overload test, minimum power setting, peak firing pressure test, turbo work cert and crankshaft work cert
- Standard and project-specific witness testing
- Spare parts kit
- Literature
- Project-specific installation drawings
- Electrical schematics and P&ID drawings